Partner: Kamila Iskhakova


Recent publications
1.Marek R., Ćwieka H., Donouhue N., Holweg P., Moosmann J., Beckmann F., Brcic I., Schwarze U. Y., Iskhakova K., Chaabane M., Sefa S., Zeller-Plumhoff B., Weinberg A., Willumeit-Römer R., Sommer N., Degradation behavior and osseointegration of Mg-Zn-Ca screws in different bone regions of growing sheep, regenerative biomaterials, ISSN: 2056-3418, DOI: 10.1093/rb/rbac077, Vol.rbac077, pp.26-60, 2022
Abstract:

Magnesium (Mg)-based implants are highly attractive for the orthopedic field and may replace titanium (Ti) as support for fracture healing. To determine the implant-bone-interaction in different bony regions, we implanted Mg-based alloy ZX00 (Mg < 0.5 Zn < 0.5 Ca, in wt%) and Ti-screws into the distal epiphysis and distal metaphysis of sheep tibiae. The implant degradation and osseointegration were assessed in vivo and ex vivo after 4, 6 and 12 weeks, using a combination of clinical computed tomography (cCT), medium-resolution micro CT (µCT) and high-resolution synchrotron radiation µCT (SRµCT). Implant volume loss, gas formation, and bone growth were evaluated for both implantation sites and each bone region independently. Additionally, histological analysis of bone growth was performed on embedded hard-tissue samples. We demonstrate that in all cases, the degradation rate of ZX00-implants ranges between 0.23-0.75 mm/year. The highest degradation rates were found in the epiphysis. Bone-to-implant-contact varied between the time points and bone types for both materials. Mostly, bone-volume-to-total-volume was higher around Ti-implants. However, we found an increased cortical thickness around the ZX00-screws when compared to the Ti-screws. Our results showed the suitability of ZX00-screws for implantation into the distal meta- and epiphysis

Keywords:

Biodegradable implants,Magnesium-based alloys,Computed tomography,Mg-Zn-Ca,Sheep,Histology

Affiliations:
Marek R.-other affiliation
Ćwieka H.-IPPT PAN
Donouhue N.-other affiliation
Holweg P.-other affiliation
Moosmann J.-other affiliation
Beckmann F.-other affiliation
Brcic I.-other affiliation
Schwarze U. Y.-other affiliation
Iskhakova K.-other affiliation
Chaabane M.-other affiliation
Sefa S.-other affiliation
Zeller-Plumhoff B.-other affiliation
Weinberg A.-other affiliation
Willumeit-Römer R.-other affiliation
Sommer N.-other affiliation
2.Zeller-Plumhoff B., Laipple D., Słomińska H., Iskhakova K., Longo E., Hermann A., Flenner S., Greving I., Storm M., Willumeit-Romer R., Evaluating the morphology of the degradation layer of pure magnesium via 3D imaging at resolutions below 40 nm, Bioactive Materials, ISSN: 2452-199X, DOI: 10.1016/j.bioactmat.2021.04.009, Vol.6, No.12, pp.4368-4376, 2021
Abstract:

Magnesium is attractive for the application as a temporary bone implant due to its inherent biodegradability, non-toxicity and suitable mechanical properties. The degradation process of magnesium in physiological environments is complex and is thought to be a diffusion-limited transport problem. We use a multi-scale imaging approach using micro computed tomography and transmission X-ray microscopy (TXM) at resolutions below 40 nm. Thus, we are able to evaluate the nanoporosity of the degradation layer and infer its impact on the degradation process of pure magnesium in two physiological solutions. Magnesium samples were degraded in simulated body fluid (SBF) or Dulbecco's modified Eagle's medium (DMEM) with 10% fetal bovine serum (FBS) for one to four weeks. TXM reveals the three-dimensional interconnected pore network within the degradation layer for both solutions. The pore network morphology and degradation layer composition are similar for all samples. By contrast, the degradation layer thickness in samples degraded in SBF was significantly higher and more inhomogeneous than in DMEM+10%FBS. Distinct features could be observed within the degradation layer of samples degraded in SBF, suggesting the formation of microgalvanic cells, which are not present in samples degraded in DMEM+10%FBS. The results suggest that the nanoporosity of the degradation layer and the resulting ion diffusion processes therein have a limited influence on the overall degradation process. This indicates that the influence of organic components on the dampening of the degradation rate by the suppression of microgalvanic degradation is much greater in the present study.

Keywords:

magnesium degradation, porosity, transmission X-ray microscopy, 3D imaging

Affiliations:
Zeller-Plumhoff B.-other affiliation
Laipple D.-other affiliation
Słomińska H.-IPPT PAN
Iskhakova K.-other affiliation
Longo E.-other affiliation
Hermann A.-other affiliation
Flenner S.-other affiliation
Greving I.-other affiliation
Storm M.-other affiliation
Willumeit-Romer R.-other affiliation
3.Meyer S., Wolf A., Sanders D., Iskhakova K., Ćwieka H., Bruns S., Flenner S., Greving I., Hagemann J., Willumeit-Römer R., Wiese B., Zeller-Plumhoff B., Degradation analysis of thin Mg-xAg wires using X-ray near-field holotomography, Metals, ISSN: 2075-4701, DOI: 10.3390/met11091422, Vol.11, No.9, pp.1422-1-12, 2021
Abstract:

Magnesium–silver alloys are of high interest for the use as temporary bone implants due to their antibacterial properties in addition to biocompatibility and biodegradability. Thin wires in particular can be used for scaffolding, but the determination of their degradation rate and homogeneity using traditional methods is difficult. Therefore, we have employed 3D imaging using X-ray near-field holotomography with sub-micrometer resolution to study the degradation of thin (250 μm diameter) Mg-2Ag and Mg-6Ag wires. The wires were studied in two states, recrystallized and solution annealed to assess the influence of Ag content and precipitates on the degradation. Imaging was employed after degradation in Dulbecco’s modified Eagle’s medium and 10% fetal bovine serum after 1 to 7 days. At 3 days of immersion the degradation rates of both alloys in both states were similar, but at 7 days higher silver content and solution annealing lead to decreased degradation rates. The opposite was observed for the pitting factor. Overall, the standard deviation of the determined parameters was high, owing to the relatively small field of view during imaging and high degradation inhomogeneity of the samples. Nevertheless, Mg-6Ag in the solution annealed state emerges as a potential material for thin wire manufacturing for implants.

Keywords:

X-ray computed tomography, magnesium-silver alloy, wire, degradation, near-field holotomography

Affiliations:
Meyer S.-other affiliation
Wolf A.-other affiliation
Sanders D.-other affiliation
Iskhakova K.-other affiliation
Ćwieka H.-IPPT PAN
Bruns S.-other affiliation
Flenner S.-other affiliation
Greving I.-other affiliation
Hagemann J.-other affiliation
Willumeit-Römer R.-other affiliation
Wiese B.-other affiliation
Zeller-Plumhoff B.-other affiliation