dr inż. Yevgen Melikhov

Zakład Biosystemów i Miękkiej Materii (ZBiMM)
Pracownia Fizyki Płynów Złożonych (PFPZ)
stanowisko: specjalista badawczo-techniczny
telefon: (+48) 22 826 12 81 wew.: 446
pokój: 327
e-mail: ymelik

Doktorat
2001-12-20Preisach Model Formalism as a Magnetic Tool for Material Investigation  (Charles University, Prague)
promotor -- dr Ivan Tomas, Charles University, Prague, Czech Republic
1408 
Ostatnie publikacje
1.Melikhov Y., Ekiel-Jeżewska M. L., Attracting dynamical modes of highly elastic fibres settling under gravity in a viscous fluid, JOURNAL OF FLUID MECHANICS, ISSN: 0022-1120, DOI: 10.1017/jfm.2024.729, Vol.994, pp.A13-1-20, 2024

Streszczenie:

The dynamics of a single highly elastic fibre settling under gravity in a very viscous fluid is studied numerically. We employ the bead model and multipole expansion of the Stokes equations, corrected for lubrication that is implemented in the precise Hydromultipole numerical codes. Four attracting regular dynamical modes of highly elastic fibres are found: two stationary shapes (one translating and the other rotating and translating), and two periodic oscillations around such shapes. The phase diagram of these modes is presented. It illustrates that the existence of each mode depends not only on the elasto-gravitation number but also on the fibre aspect ratio. Characteristic time scales, fibre deformation patterns and motion in the different modes are determined.

Słowa kluczowe:

stokesian dynamics, particle/fluid flows

Afiliacje autorów:

Melikhov Y.-IPPT PAN
Ekiel-Jeżewska M. L.-IPPT PAN
140p.
2.Demchenko Iraida N., Nikiforow K., Chernyshova M., Melikhov Y., Syryanyy Y., Korsunska N., Khomenkova L., Brodnikovskyi Y., Brodnikovskyi D., X-ray Photoelectron Spectroscopy Analysis of Scandia-Ceria-Stabilized Zirconia Composites with Different Transport Properties, Materials, ISSN: 1996-1944, DOI: 10.3390/ma16165504, Vol.16, No.16, pp.5504-1-12, 2023

Streszczenie:

This work aims to study a possible modification in the electronic structure of scandia-ceria-stabilized zirconia (10Sc1CeSZ) ceramics sintered at different temperatures. In addition to using X-ray diffraction (XRD), scanning electron microscopy (SEM) and impedance spectroscopy to investigate the structural and electrical properties, we employed X-ray photoelectron spectroscopy (XPS) to determine the chemical state information of the atoms involved, along with compositional analysis. As expected, a significant increase in grain ionic conductivity with the sintering temperature was present. This increase was accompanied by a decrease in the porosity of the samples, an increase in the grain size, and a transformation from the rhombohedral to the cubic phase. The phase transformation was detected not only using XRD, but also using XPS and, for this type of ceramic, XPS detected this transformation for the first time. In addition to the changes in the structural characteristics, the increase in the ionic conductivity was accompanied by a modification in the electronic structure of the ceramic surface. The XPS results showed that the surface of the ceramic sintered at the lower temperature of 1100 °C had a higher amount of Zr–OH bonds than the surface of the ceramic sintered at the higher temperature of 1400 °C. The existence of these Zr–OH bonds was confirmed using Fourier-transform infrared spectroscopy (FTIR). From this result, taken together with the difference between the oxygen/zirconium ratios in these ceramics, also identified using XPS, we conclude that there were fewer oxygen vacancies in the ceramic sintered at the lower temperature. It is argued that these two factors, together with the changes in the structural characteristics, have a direct influence on the conductive properties of the studied ceramics sintered at different temperatures.

Słowa kluczowe:

XPS, zirconia, scandia-ceria-stabilized zirconia, ScCSZ, SOFC

Afiliacje autorów:

Demchenko Iraida N.-Institute of Physics, Polish Academy of Sciences (PL)
Nikiforow K.-other affiliation
Chernyshova M.-Institute of Plasma Physics and Laser Microfusion (PL)
Melikhov Y.-IPPT PAN
Syryanyy Y.-Institute of Physics, Polish Academy of Sciences (PL)
Korsunska N.-other affiliation
Khomenkova L.-other affiliation
Brodnikovskyi Y.-other affiliation
Brodnikovskyi D.-other affiliation
140p.
3.Wang Y., Melikhov Y., Meydan T., Dipole modelling of temperature-dependent magnetic flux leakage, NDT AND E INTERNATIONAL, ISSN: 0963-8695, DOI: 10.1016/j.ndteint.2022.102749, Vol.133, pp.102749-1-9, 2023

Streszczenie:

Due to the nonlinear coupling, assessing the direct effect of temperature on magnetic flux leakage (MFL) signal is a complicated task. If temperature induces inner stress, it makes the problem doubly difficult, so few models are available for predicting the MFL signal under this condition. To model the effect of temperature on MFL signal, the temperature-dependent magnetic dipole models are proposed. In the first case, where the direct thermal effect is involved only, the dipole model is improved via the modified temperature-dependent Jiles-Atherton (J-A) model. While in the second case, where the combined effects of temperature and thermal stress are considered, the magnetomechanical J-A parameters are further introduced into the dipole model. The thermal stress distribution around a cylindrical through-hole defect is solved by thermoelastic and solid mechanics theories. The magnetomechanical theory is employed to analyse the stress-dependent magnetisation distribution, the key parameter in the magnetic dipole model. The verified experiments are conducted on an M250-50A non-oriented grain (NO) silicon steel specimen with a cylindrical through-hole defect. And the MFL signals predicted by both proposed models agree with the experimental results. When the direct effect of temperature is involved only, the peak-to-peak amplitude of the MFL signal (MFLpp) presents approximately linear dependence on temperature in the range from −40 to 60 . In addition, when both temperature and thermal stress are considered, the MFLpp changes as a parabolic function of temperature, this being much more significant than the direct effect. The proposed models can act as effective tools to understand the temperature and thermal stress influences on MFL signals. They are also appropriate to solve the inverse problem of sizing the defects accurately when the temperature is involved.

Słowa kluczowe:

Magnetic dipole model, Magnetic flux leakage, Temperature, J-A model, Thermal stress, Magnetomechanics

Afiliacje autorów:

Wang Y.-Beijing Aeronautical Manufacturing Technology Research Institute (CN)
Melikhov Y.-IPPT PAN
Meydan T.-Cardiff University (GB)
140p.
4.Shashank H., Melikhov Y., Ekiel-Jeżewska M.L., Dynamics of ball chains and highly elastic fibres settling under gravity in a viscous fluid, SOFT MATTER, ISSN: 1744-683X, DOI: 10.1039/D3SM00255A, Vol.19, No.26, pp.4829-4846, 2023

Streszczenie:

We study experimentally the dynamics of one and two ball chains settling under gravity in a highly viscous silicon oil at a Reynolds number much smaller than unity. We record the motion and shape deformation using two cameras. We demonstrate that single ball chains in most cases do not tend to be planar and often rotate, not keeping the ends at the same horizontal level. Shorter ball chains usually form shapes resembling distorted U. Longer ones in the early stage of the evolution form a shape resembling distorted W, and later deform non-symmetrically and significantly out of a plane. The typical evolution of shapes observed in our experiments with single ball chains is reproduced in our numerical simulations of a single elastic filament. In the computations, the filament is modelled as a chain of beads. Consecutive beads are connected by springs. Additional springs link consecutive pairs of beads. Elastic forces are assumed to be much smaller than gravity. As a result, the fibre is very flexible. We assume that the fluid sticks to the surfaces of the beads. We perform multipole expansion of the Stokes equations, with a lubrication correction. This method is implemented in the precise HYDROMULTIPOLE numerical codes. In our experiments, two ball chains, initially one above the other, later move away or approach each other, for a larger or smaller initial distance, respectively.

Afiliacje autorów:

Shashank H.-IPPT PAN
Melikhov Y.-IPPT PAN
Ekiel-Jeżewska M.L.-IPPT PAN
140p.
5.Wang Y., Melikhov Y., Meydan T., Multifunctional induction coil sensor for evaluation of carbon content in carbon steel, IEEE TRANSACTIONS ON MAGNETICS, ISSN: 0018-9464, DOI: 10.1109/TMAG.2022.3217954, Vol.59, No.2, pp.6000305-1-5, 2023

Streszczenie:

Carbon steel has proven to be an important structural and functional material that plays an irreplaceable role in the worldwide economy. The influence of carbon on the mechanical and magnetic properties of the steel is well understood. Thus, the precise knowledge of the amount of carbon content in steel is crucial. Magnetic Barkhausen noise (MBN), magnetic hysteresis loop (MHL) and impedance measurements are reliable tools to assess carbon content. In this work, a multifunctional induction coil sensor used for MBN, MHL and impedance measurements is designed and optimised. A multifunctional measurement system using the optimised induction coil is employed to measure MBN, MHL and impedance signals. The parabolic dependence of the maximum value of MBN envelope on carbon content in steel is theoretically analysed and experimentally verified. Coercive field and remanence from MHL measurements as well as the maximum impedance value are found to be proportional to carbon content and their dependence is explained with analytical simulations.

Słowa kluczowe:

Carbon content ,Impedance ,Magnetic Barkhausen Noise ,Magnetic Hysteresis Loop ,Multifunctional sensor

Afiliacje autorów:

Wang Y.-Beijing Aeronautical Manufacturing Technology Research Institute (CN)
Melikhov Y.-IPPT PAN
Meydan T.-Cardiff University (GB)
70p.
6.Shokri A., Melikhov Y., Syryanyy Y., Demchenko Iraida N., Point Defects in Silicon-Doped β-Ga2O3: Hybrid-DFT Calculations, ACS Omega, ISSN: 2470-1343, DOI: 10.1021/acsomega.3c05557, Vol.8, No.46, pp.43732-43738, 2023

Streszczenie:

In this work, hybrid density functional theory calculations are used to evaluate the structural and electronic properties and formation energies of Si-doped β-Ga2O3. Overall, eight interstitial (Sii) and two substitutional (SiGa) positions are considered. In general, our results indicate that the formation energy of such systems is significantly influenced by the charge state of the defect. It is confirmed that it is energetically more favorable for the substitution process to proceed under Ga-poor growth conditions than under Ga-rich growth conditions. Furthermore, it is confirmed that the formation of SiGaI with a tetrahedral coordination geometry is more favorable than the formation of SiGaII with an octahedral one. Out of all considered interstitial positions, due to the negative formation energy of the Si +3 charge state at i8 and i9 interstitial positions over the wide range of Fermi energy, this type of defect can be spontaneously stable. Finally, due to a local distortion caused by the presence of the interstitial atom as well as its charge state, these systems obtain a spin-polarized ground state with a noticeable magnetic moment.

Afiliacje autorów:

Shokri A.-other affiliation
Melikhov Y.-IPPT PAN
Syryanyy Y.-Institute of Physics, Polish Academy of Sciences (PL)
Demchenko Iraida N.-Institute of Physics, Polish Academy of Sciences (PL)
70p.
7.Chernyshova M., Malinowski K., Jablonski S., Melikhov Y., Wojenski A., Kasprowicz G., Fornal T., Imrisek M., Jaulmes F., Weinzettl V., 2D GEM-based SXR imaging diagnostics for plasma radiation: Preliminary design and simulations, Nuclear Materials and Energy, ISSN: 2352-1791, DOI: 10.1016/j.nme.2022.101306, Vol.33, pp.101306-1-7, 2022

Streszczenie:

The purpose of this research is to design and construct a plasma radiation imaging system for fusion devices which is focused on soft X-ray region from about 2 to 15 keV photon energy. The proposed 2D diagnostic system, as opposed to conventional 1D systems, is expected to benefit from tangential field of view and to deliver new data for toroidal phenomena observations. This contribution relates to the introductory development of such 2D system laying out details on the overall design of the detecting unit (based on GEM technology) as well as on its acquisition module. The results cover also the expected photon flux and spectra foreseen for COMPASS-U device, as a first choice for testing and verification. Considerations on working medium and internal structure of the detecting sensor are presented including electrodes configurations and collecting electrode pattern. The preliminary establishments for data acquisition system are presented as well.

Słowa kluczowe:

Plasma physics, Plasma radiation diagnostics, SXR imaging detector, Micropattern gaseous detectors (MSGC; GEM; THGEM; RETHGEM; MHSP; MICROPIC, MICROMEGAS; InGrid; etc.), Gas electron multiplier, Detector simulations

Afiliacje autorów:

Chernyshova M.-Institute of Plasma Physics and Laser Microfusion (PL)
Malinowski K.-Institute of Plasma Physics and Laser Microfusion (PL)
Jablonski S.-other affiliation
Melikhov Y.-IPPT PAN
Wojenski A.-other affiliation
Kasprowicz G.-Politechnika Warszawska (PL)
Fornal T.-other affiliation
Imrisek M.-other affiliation
Jaulmes F.-other affiliation
Weinzettl V.-other affiliation
100p.
8.Syryanyy Y., Zając M., Guziewicz E., Wozniak W., Melikhov Y., Chernyshova M., Ratajczak R., Demchenko I.N., Polarized dependence of soft X-ray absorption near edge structure of ZnO films implanted by Yb, Materials Science in Semiconductor Processing, ISSN: 1369-8001, DOI: 10.1016/j.mssp.2022.106609, Vol.144, pp.106609-1-8, 2022

Streszczenie:

Virgin and Yb-implanted epitaxial ZnO films grown using atomic layer deposition (ALD) were investigated by X-ray absorption spectroscopy (XAS). XAS study revealed a strong polarization dependence of films determined by the orientation of the polarization vector of the synchrotron radiation to the sample surface. It also indicated that the implantation and subsequent annealing have an important influence on the native point defect complexes in the ZnO. Comparison of experimental spectra with the modelled ones, which are computed based on the linear combination of model spectra corresponding to the selected point defects and their complexes, confirmed the presence of donor-acceptor complexes (mVZn - nVO, m = 1,4; n = 1,2) in the samples under study. The mechanism of vacancy complexes formation is unclear as it takes place under non-equilibrium conditions, for which any theoretical method has not been well established. Exploring the 3 d → 4 f absorption, it was found that oxidation state of Yb in ZnO is 3+, which is consistent with the XPS findings and previously conducted Resonant Photoemission Spectroscopy (RPES) investigations. The inversion of the polarization dependence for samples with different Yb fluences visible in Yb M5 spectra can be associated with a tilt of the oxygen pseudo octahedra or/and with their distortion. The analysis of the presented data suggests that the donor-acceptor complexes are present both in as grown and implanted films and may influence their electrical properties. This suggestion was confirmed by previous Hall measurements showing that the resistivity of annealed ZnO:Yb film with a fluence of 5e15 ions/cm2 decreases by about one order compared to the one with a fluence of 5e14 ions/cm2.

Afiliacje autorów:

Syryanyy Y.-Institute of Physics, Polish Academy of Sciences (PL)
Zając M.-Warsaw University of Life Sciences (PL)
Guziewicz E.-Institute of Physics, Polish Academy of Sciences (PL)
Wozniak W.-Institute of Physics, Polish Academy of Sciences (PL)
Melikhov Y.-IPPT PAN
Chernyshova M.-Institute of Plasma Physics and Laser Microfusion (PL)
Ratajczak R.-National Centre for Nuclear Research (PL)
Demchenko I.N.-Institute of Physics, Polish Academy of Sciences (PL)
70p.
9.Chernyshova M., Malinowski K., Jabłoński S., Casiraghi I., Demchenko I.N., Melikhov Y., Development of 2D GEM-based SXR plasma imaging for DTT device: focus on readout structure, Fusion Engineering and Design, ISSN: 0920-3796, DOI: 10.1016/j.fusengdes.2021.112443, Vol.169, pp.112443-1-12, 2021

Streszczenie:

Creation and development of a new diagnostics useful for future thermonuclear reactors and helpful in studying impurity profiles, MHD modes/localization, and imaging are among urgent tasks in plasma research field. Global SXR imaging for DTT device in support of power exhaust programme and its consecutive impact for plasma core is an example of applicability of such diagnostics. This contribution presents the results of the ongoing development of the elaborated plasma X-ray imaging technology focusing on the design of the relevant structure of readout electrode. In order to achieve that, the details on the expected plasma radiation for the selected scenario for DTT machine were assessed. Then, the spatial distribution of plasma radiation intensity flux that will be reaching the detector window of the GEM based detector was simulated. Taking it into account along with the physical properties of the detector, the spatial and temporal distributions of charge cloud that will be reaching the readout plane were evaluated. The special design of the readout structure has been proposed that fulfil critical conditions originated from technological and physical constraints. The final effectiveness of the GEM based detector was evaluated proving that such detector is well suited for an effective plasma radiation imaging.

Słowa kluczowe:

X-ray detectors, GEM detector simulations, gas-electron multiplier (GEM) detector, SXR plasma imaging, DTT device

Afiliacje autorów:

Chernyshova M.-Institute of Plasma Physics and Laser Microfusion (PL)
Malinowski K.-Institute of Plasma Physics and Laser Microfusion (PL)
Jabłoński S.-Institute of Plasma Physics and Laser Microfusion (PL)
Casiraghi I.-other affiliation
Demchenko I.N.-Institute of Physics, Polish Academy of Sciences (PL)
Melikhov Y.-IPPT PAN
100p.
10.Wang Y., Meydan T., Melikhov Y., Quantitative evaluation of the effect of temperature on magnetic Barkhausen noise, SENSORS, ISSN: 1424-8220, DOI: 10.3390/s21030898, Vol.21, No.3, pp.898-1-18, 2021

Streszczenie:

The effect of temperature on magnetic Barkhausen noise (MBN) can be divided into two types: the direct effect of temperature itself and the indirect effect of thermally induced stress. The theoretical model is proposed in this paper to describe the effects of temperature on the MBN signal. For the case considering the direct effect of temperature only, the analytical model allows the prediction of the effect of temperature on MBN profile, and, based on the model, a simple linear calibration curve is presented to evaluate the effect of temperature on MBN amplitude quantitatively. While for the case where the indirect effect of thermal stress is taken into account in addition to the direct effect, the proposed theoretical model allows the deduction of parabolic function for quantitative evaluation of the combined effect on MBN. Both effects of temperature on MBN, i.e., the direct only and the combined one, have been studied experimentally on 0.5 mm thickness non-oriented (NO) electrical steel and the adhesive structure of NO steel and ceramic glass, respectively. The reciprocal of the measured MBN peak amplitude (1/MBNp) in the first case shows a linear function of temperature, which agrees with the proposed linear calibration curve. While in the experiments considering the combined effects, 1/MBNp shows parabolic dependence on temperature, which is further simplified as a piecewise function for the practical applications.

Słowa kluczowe:

magnetic Barkhausen noise, temperature, thermal stress, nondestructive evaluation

Afiliacje autorów:

Wang Y.-Beijing Aeronautical Manufacturing Technology Research Institute (CN)
Meydan T.-Cardiff University (GB)
Melikhov Y.-IPPT PAN
100p.
11.Demchenko I.N., Melikhov Y., Walczak M.S., Ratajczak R., Sobczak K., Barcz A., Minikaev R., Dynowska E., Domagała J.Z., Chernyshova M., Syryanyy Y., Gavrilov N.V., Sawicki M., Effect of rapid thermal annealing on damage of silicon matrix implanted by low-energy rhenium ions, JOURNAL OF ALLOYS AND COMPOUNDS, ISSN: 0925-8388, DOI: 10.1016/j.jallcom.2020.156433, Vol.846, pp.156433-1-10, 2020

Streszczenie:

The structural, electronic, and magnetic properties of low-energy rhenium implanted c-Si are examined for the first time. The damage created by rhenium ions and the following partial reconstruction of the silicon host matrix after rapid thermal annealing (RTA) are investigated as a function of the fluence. Rutherford backscattering spectrometry (RBS) results reveal that the implanted ions are located in the near-surface region with the distribution maximum at about 23 nm below the surface. The analysis of rhenium-depth distribution using the McChasy code shows that the implanted Re-ions are located in the interstitial lattice positions. The RTA leads to a partial recovery of the silicon crystal structure. According to the RBS results, the formed inclusions are not coherent with the silicon host matrix causing an increase of the lattice distortion. Analysis of channeled RBS/c spectra carried out by the McChasy code revealed different levels of bent channels in damaged regions suggesting bimodal distribution of inclusions in the silicon. Studies of high-resolution X-ray photoelectron spectroscopy (XPS) conducted after the RTA showed the shift of Re 4f7/2 binding energy (BE) by +0.68 and + 0.85 eV with respect to metallic rhenium for the samples with lower/higher fluencies, respectively. Complex XPS, density functional theory (DFT) simulations, and transmission electron microscopy (TEM) data analysis allowed us to conclude that the near-surface layer of the sample (~10 nm) consists of nanoinclusions with cubic and/or hexagonal ReSi. In the middle area of the samples, much larger nanoinclusions (>10/20 nm for higher/lower fluencies, respectively) containing pure metallic rhenium inside are formed. The RTA increases the magnetic moment of the sample with the lower dose nearly 20-fold, whereas in the sample with the higher dose a 3-fold increment is observed only. The magnetic response of the examined systems after the RTA indicates a presence of magnetic interactions between the nanoinclusions resulting in the system exhibiting super-spin glass or super-ferromagnetism.

Słowa kluczowe:

rhenium-implanted silicon, RBS, XPS, RTA, TEM, DFT

Afiliacje autorów:

Demchenko I.N.-Institute of Physics, Polish Academy of Sciences (PL)
Melikhov Y.-IPPT PAN
Walczak M.S.-University of Manchester (GB)
Ratajczak R.-National Centre for Nuclear Research (PL)
Sobczak K.-other affiliation
Barcz A.-Institute of Physics, Polish Academy of Sciences (PL)
Minikaev R.-other affiliation
Dynowska E.-other affiliation
Domagała J.Z.-Institute of Physics, Polish Academy of Sciences (PL)
Chernyshova M.-Institute of Plasma Physics and Laser Microfusion (PL)
Syryanyy Y.-Institute of Physics, Polish Academy of Sciences (PL)
Gavrilov N.V.-other affiliation
Sawicki M.-other affiliation
100p.
12.Chernyshova M., Malinowski K., Czarski T., Demchenko I.N., Melikhov Y., Kowalska-Strzęciwilk E., Wojeński A., Krawczyk R.D., Effect of charging-up and regular usage on performance of the triple GEM detector to be employed for plasma radiation monitoring, Fusion Engineering and Design, ISSN: 0920-3796, DOI: 10.1016/j.fusengdes.2020.111755, Vol.158, pp.111755-1-6, 2020

Streszczenie:

After the problem of high-temperature plasma confinement, construction of diagnostics that is able to identify plasma contamination with impurities and to determine impurity distribution is another critically important issue. Solution of this problem would enable progress towards the success in controlled thermonuclear fusion. A new diagnostics, based on Gas Electron Multiplier (GEM) technology, has been recently developed for poloidal tomography focused on radiation of the metal impurities by monitoring in Soft X-Ray (SXR) region. GEM based detectors would undergo much less damage by neutrons than standard semiconductor diodes which results in better operational stability. This paper emphasizes the results of the latest examination of this type of detectors, showing influence of the charging-up effect on the detector performance and its physical properties for expected plasma radiation intensity. In addition, an undesired influence of aging of the detector window's material on the performance of the GEM detector is also shown: regular (moderate or active) usage could lead to changes of material's morphology as well as its composition. This study confirms the importance of further research into material’s optimization of GEM detectors used as a base for SXR tomographic diagnostics aimed to work under different plasma radiation conditions.

Słowa kluczowe:

nuclear instruments for hot plasma diagnostics, X-ray detectors, electron multipliers (gas), micropattern gaseous detectors, charging-up effect, detector window's material

Afiliacje autorów:

Chernyshova M.-Institute of Plasma Physics and Laser Microfusion (PL)
Malinowski K.-Institute of Plasma Physics and Laser Microfusion (PL)
Czarski T.-Institute of Plasma Physics and Laser Microfusion (PL)
Demchenko I.N.-Institute of Physics, Polish Academy of Sciences (PL)
Melikhov Y.-other affiliation
Kowalska-Strzęciwilk E.-Institute of Plasma Physics and Laser Microfusion (PL)
Wojeński A.-Politechnika Warszawska (PL)
Krawczyk R.D.-Politechnika Warszawska (PL)
100p.
13.Wang Y., Melikhov Y., Meydan T., Yang Z., Wu D., Wu B., He C., Liu X., Stress-dependent magnetic flux leakage: finite element modelling simulations versus experiments, JOURNAL OF NONDESTRUCTIVE EVALUATION, ISSN: 0195-9298, DOI: 10.1007/s10921-019-0643-0, Vol.39, pp.1-1-9, 2020

Streszczenie:

Assessing the effect of defect induced stresses on magnetic flux leakage (MFL) signals is a complicated task due to nonlinear magnetomechanical coupling. To facilitate the analysis, a multi-physics finite elemental simulation model is proposed based on magnetomechanical theory. The model works by quasi-statically computing the stress distribution in the specimen, which is then inherited to solve the nonlinear magnetic problem dynamically. The converged solution allows identification and extraction of the MFL signal induced by the defect along the sensor scanning line. Experiments are conducted on an AISI 1045 steel specimen, i.e. a dog-bone shaped rod with a cylindrical square-notch defect. The experiments confirm the validity of the proposed model that predicted a linear dependency of the peak-to-peak amplitude of the normalized MFL signal on applied stress. Besides identifying the effect of stress on the induced MFL signal, the proposed model is also suitable for solving the inverse problem of sizing the defects when stress is involved.

Słowa kluczowe:

magnetic flux leakage, magnetomechanics, Jiles–Atherton model, non-destructive testing, finite element method, multiphysics numerical simulation

Afiliacje autorów:

Wang Y.-Beijing Aeronautical Manufacturing Technology Research Institute (CN)
Melikhov Y.-other affiliation
Meydan T.-Cardiff University (GB)
Yang Z.-other affiliation
Wu D.-other affiliation
Wu B.-other affiliation
He C.-other affiliation
Liu X.-Imperial College London (GB)
100p.
14.Kuczera K., Jas G.S., Ekiel-Jeżewska M.L., Melikhov Y., Reorientation motions of N-acetyl-tryptophan-amide (NATA dipeptide) in aqueous solution and with co-solvents: molecular dynamics vs hydrodynamic model, PHYSICS OF FLUIDS, ISSN: 1070-6631, DOI: 10.1063/5.0031554, Vol.32, pp.127111-1-14, 2020

Streszczenie:

We present a study of peptide reorientational dynamics in solution analyzed from the perspective of fluorescence anisotropy decay (FAD) experiments, and atomistic molecular dynamics (MD) and continuum hydrodynamics modeling. Earlier, FAD measurements and MD simulations of the model dipeptide N-acetyltryptophanamide (NATA) in explicit water and in aqueous solutions of urea, guanidinium chloride, and proline co-solvents identified excellent agreement of MD results with experimental data, indicating the presence of significant effects of peptide–solvent interactions, and the overall tumbling of the peptide could be well described by contributions from individual conformers, represented by dihedral-restrained MD. Here, we extend these studies by analyzing dynamic inhomogeneity in the solutions and by developing a hydrodynamic model (HM) of the conformer dynamics. The MD simulation data indicate the presence of markedly different dynamic microenvironments for the four studied solutions, with the average water reorientations being different in all systems, partly reflecting the bulk viscosities. Additionally, the water dynamics also exhibited a marked slowdown in the vicinity of the co-solvents, especially chloride and proline. To gain further insight, we applied the HM to predict rotational correlation times of tryptophan for the individual NATA conformers identified in MD. The hydrodynamic results were in very good agreement with MD simulations for the individual structures, showing that the HM model provides a realistic description of rotational diffusion for rigid peptide structures. Overall, our study generated new microscopic insights into the complex nature of the structure and dynamics of peptide solvation shells for systems containing water and denaturing and stabilizing co-solvents.

Afiliacje autorów:

Kuczera K.-other affiliation
Jas G.S.-University of Kansas (US)
Ekiel-Jeżewska M.L.-IPPT PAN
Melikhov Y.-IPPT PAN
100p.
15.Chernyshova M., Malinowski K., Czarski T., Kowalska-Strzęciwilk E., Linczuk P., Wojeński A., Krawczyk R.D., Melikhov Y., Advantages of Al based GEM detector aimed at plasma soft−semi hard X-ray radiation imaging, Fusion Engineering and Design, ISSN: 0920-3796, DOI: 10.1016/j.fusengdes.2019.01.153, Vol.146, pp.1039-1042, 2019

Streszczenie:

Development of gaseous detectors, more specifically Gas Electron Multiplier (GEM) based detectors, for application at tokamak plasma radiation monitoring/imaging in Soft−Semi Hard X-ray (S−SH) region is an ongoing research activity aiming to deliver valuable information on plasma shape, magnetic configuration, non-axisymmetry phenomena of the plasma, etc. Wide radiation range and brightness of plasma radiation impose some restrictions on choice of materials in the detecting chamber, as their interaction with the incident radiation may disrupt original signals. This work proposes usage of aluminum as GEM foils electrodes for the first time. The detector based on these foils was constructed and examined. The operational characteristics and spectral capabilities of such detector were compared with the ones based on the standard (commonly used) copper GEM foils. The laboratory tests were performed using X-ray tube and 55Fe sources to examine detectors' capabilities in energy-resolved imaging. Additionally, simulations of origin and number of the generated electrons, which determine the detector signal, were performed for Al and Cu GEM foils for a wide energy range of incident photons. The experimental and modelling data demonstrated that Cu based GEM detector produces higher parasitic signal than Al one necessitating total elimination of copper from detector's chamber.

Słowa kluczowe:

nuclear instruments for hot plasma diagnostics, X-ray detectors, SXR imaging, electron multipliers (gas), micropattern gaseous detectors, aluminum GEM foils

Afiliacje autorów:

Chernyshova M.-Institute of Plasma Physics and Laser Microfusion (PL)
Malinowski K.-Institute of Plasma Physics and Laser Microfusion (PL)
Czarski T.-Institute of Plasma Physics and Laser Microfusion (PL)
Kowalska-Strzęciwilk E.-Institute of Plasma Physics and Laser Microfusion (PL)
Linczuk P.-Institute of Plasma Physics and Laser Microfusion (PL)
Wojeński A.-Politechnika Warszawska (PL)
Krawczyk R.D.-Politechnika Warszawska (PL)
Melikhov Y.-IPPT PAN
100p.
16.Demchenko I.N., Ratajczak R., Melikhov Y., Konstantynov P., Guziewicz E., Valence band of ZnO:Yb probed by resonant photoemission spectroscopy, Materials Science in Semiconductor Processing, ISSN: 1369-8001, DOI: 10.1016/j.mssp.2018.11.037, Vol.91, pp.306-309, 2019

Streszczenie:

Resonant photoemission spectroscopy (RPES), which is a useful tool for extracting photoemission response of the localized Rare Earth (RE) impurity levels from the host electronic band structure, was used to study ZnO:Yb films. The resonant enhancement of the photoemission signal at binding energy around 7.5 and 11.7 eV was observed when photon energy was tuned to the Yb 4d-4f absorption threshold (182 eV). It was found that the 4f and the valence band (VB) maximum binding energies do not depend on the Yb dose, suggesting that the measurement of only one concentration is sufficient to determine the binding energies of the Yb 4f in the examined system. Subsequent annealing did not change the arrangements of implanted ytterbium atoms in host matrix: the majority of them remain in 3 + state having pseudo-octahedral local arrangement similar to Yb2O3.

Afiliacje autorów:

Demchenko I.N.-Institute of Physics, Polish Academy of Sciences (PL)
Ratajczak R.-National Centre for Nuclear Research (PL)
Melikhov Y.-IPPT PAN
Konstantynov P.-Institute of Physics, Polish Academy of Sciences (PL)
Guziewicz E.-Institute of Physics, Polish Academy of Sciences (PL)
70p.
17.Hussain M., Misbah-ul-Islam , Meydan T., Cuenca J.A., Melikhov Y., Mustafa G., Murtaza G., Jamil Y., Microwave absorption properties of CoGd substituted ZnFe2O4 ferrites synthesized by co-precipitation technique, CERAMICS INTERNATIONAL, ISSN: 0272-8842, DOI: 10.1016/j.ceramint.2017.12.145, Vol.44, No.6, pp.5909-5914, 2018

Streszczenie:

A series of co-precipitated Zn1-xCoxGdyFe2-yO4 spinel ferrites (x = 0.0-0.5, y = 0.00-0.10) sintered at 1000 degrees C were characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), vibrating sample magnetometery (VSM) and microwave cavity perturbation (MCP). XRD patterns and FTIR spectra reveal formation of the spinel phase along with few traces of GdFeO3 second phase. The lattice constant decreases with an increasing amount of CoGd ions due to the segregation of Gd3+ on the grain boundaries and due to replacement of lager Zn2+ ions with smaller Co2+ ions. SEM shows grain size to decrease with the increase of CoGd contents due to grain growth inhibition by the second phase. VSM results show remanence and saturation magnetization to exhibit an increasing trend due to Co substitution on octahedral sites and presence of a second phase. The coercivity increases with the increase of CoGd contents due to anisotropic nature of Co. MCP shows the complex magnetic permeability to increase with CoGd concentration while the complex permittivity decreases.

Słowa kluczowe:

Spinel ferrites, Magnetization, Permittivity, Permeability

Afiliacje autorów:

Hussain M.-Bahauddin Zakariya University (PK)
Misbah-ul-Islam -Bahauddin Zakariya University (PK)
Meydan T.-Cardiff University (GB)
Cuenca J.A.-Cardiff University (GB)
Melikhov Y.-IPPT PAN
Mustafa G.-Bahauddin Zakariya University (PK)
Murtaza G.-Bahauddin Zakariya University (PK)
Jamil Y.-University of Agriculture (PK)
40p.
18.Demchenko I.N., Syryanyy Y., Melikhov Y., Nittler L., Gladczuk L., Lasek K., Cozzarini L., Dalmiglio M., Goldoni A., Konstantynov P., Chernyshova M., X-ray photoelectron spectroscopy analysis as a tool to assess factors influencing magnetic anisotropy type in Co/MgO system with gold interlayer, SCRIPTA MATERIALIA, ISSN: 1359-6462, DOI: 10.1016/j.scriptamat.2017.10.006, Vol.145, pp.50-53, 2018

Streszczenie:

X-ray photoelectron spectroscopy (XPS) studies of Au/Co/Au(0.3 nm)/MgO and Au/Co/MgO systems were conducted in order to monitor the electronic structure modification at Co/MgO interface with/without gold interlayer. A detailed analysis of Co 2p states revealed that the amount of minor oxygen contribution at Co/MgO interface decreased after the Au interlayer was added. The obtained XPS results together with density functional theory (DFT) allowed explanation of the increase of surface anisotropy energy in the sample with the gold interlayer in terms of (i) noble and transitional metal d-d orbital hybridization; (ii) interfacial Co 3d and O 2p; and (iii) interface imperfection.

Afiliacje autorów:

Demchenko I.N.-Institute of Physics, Polish Academy of Sciences (PL)
Syryanyy Y.-Institute of Physics, Polish Academy of Sciences (PL)
Melikhov Y.-IPPT PAN
Nittler L.-Institute of Physics, Polish Academy of Sciences (PL)
Gladczuk L.-Institute of Physics, Polish Academy of Sciences (PL)
Lasek K.-Institute of Physics, Polish Academy of Sciences (PL)
Cozzarini L.-Elettra-Sincrotrone Trieste S.C.p.A. (IT)
Dalmiglio M.-Elettra-Sincrotrone Trieste S.C.p.A. (IT)
Goldoni A.-Elettra-Sincrotrone Trieste S.C.p.A. (IT)
Konstantynov P.-Institute of Physics, Polish Academy of Sciences (PL)
Chernyshova M.-Institute of Plasma Physics and Laser Microfusion (PL)
35p.
19.Chernyshova M., Malinowski K., Melikhov Y., Kowalska-Strzęciwilk E., Czarski T., Wojeński A., Linczuk P., Krawczyk R.D., Study of the optimal configuration for a Gas Electron Multiplier aimed at plasma impurity radiation monitoring, Fusion Engineering and Design, ISSN: 0920-3796, DOI: 10.1016/j.fusengdes.2018.03.031, Vol.136, pp.592-596, 2018

Streszczenie:

For the purpose of monitoring the level of plasma impurity (especially tungsten) and its distribution reconstruction at tokamaks (ITER in particular), a Soft X-Ray (SXR) tomographic diagnostics based on Gas Electron Multiplier (GEM) detectors with energy discrimination has been extensively considered for a while. Coupled with advanced electronics, GEM detectors offer excellent time and space resolution, as well as a charge spectrum from which the SXR photon spectrum can be deconvolved. In addition, they are less subjected to a neutron damage as compared to standard semiconductor diodes. This contribution highlights the latest studies supporting the development of such diagnostics focusing on laboratory tests to examine: (a) the impact of GEM holes geometry on the properties and distribution of the electron avalanche; (b) the effect of the high rate photon flux on GEM foil performance; and (c) the optimal electric field distribution.

Słowa kluczowe:

Nuclear instruments for hot plasma diagnostics, X-ray detectors, Electron multipliers (gas), Micropattern gaseous detectors (MSGC; GEM; THGEM; RETHGEM; MHSP; MICROPIC; MICROMEGAS; InGrid; etc.)

Afiliacje autorów:

Chernyshova M.-Institute of Plasma Physics and Laser Microfusion (PL)
Malinowski K.-Institute of Plasma Physics and Laser Microfusion (PL)
Melikhov Y.-IPPT PAN
Kowalska-Strzęciwilk E.-Institute of Plasma Physics and Laser Microfusion (PL)
Czarski T.-Institute of Plasma Physics and Laser Microfusion (PL)
Wojeński A.-Politechnika Warszawska (PL)
Linczuk P.-Institute of Plasma Physics and Laser Microfusion (PL)
Krawczyk R.D.-Politechnika Warszawska (PL)
30p.
20.Chernyshova M., Czarski T., Malinowski K., Melikhov Y., Kasprowicz G., Kowalska-Strzęciwilk E., Linczuk P., Wojeński A., Krawczyk R.D., 2D GEM based imaging detector readout capabilities from perspective of intense soft x-ray plasma radiation, REVIEW OF SCIENTIFIC INSTRUMENTS, ISSN: 0034-6748, DOI: 10.1063/1.5039278, Vol.89, No.10, pp.10G106-1-5, 2018

Streszczenie:

A detecting system based on the Gas Electron Multiplier (GEM) technology is considered for tokamak plasma radiation monitoring. In order to estimate its capabilities in processing and recording intense photon flux (up to similar to 0.1 MHz/mm(2)), the imaging effectiveness of GEM detectors was tested with different patterned anode planes (i. e., different signal readouts): a simple hexagonal readout structure and three structures with interconnected electrodes (XY square, XY rectangular, and UXV). It was found that under intense photon flux, all the readouts fail to account for a considerable amount of the incoming signals due to mostly photon position determination ambiguity and overlapped signals. Analysis of the signals that can be used to determine photon position and energy unambiguously showed that the UXV readout structure is more effective among the readouts with interconnected electrodes. Along with similar spatial resolution and accuracy, the UXV based layout could be considered as a quite promising base of the interconnected anode electrodes configuration, keeping in mind that the photon rate capability has to be improved for the final application.

Afiliacje autorów:

Chernyshova M.-Institute of Plasma Physics and Laser Microfusion (PL)
Czarski T.-Institute of Plasma Physics and Laser Microfusion (PL)
Malinowski K.-Institute of Plasma Physics and Laser Microfusion (PL)
Melikhov Y.-IPPT PAN
Kasprowicz G.-Politechnika Warszawska (PL)
Kowalska-Strzęciwilk E.-Institute of Plasma Physics and Laser Microfusion (PL)
Linczuk P.-Institute of Plasma Physics and Laser Microfusion (PL)
Wojeński A.-Politechnika Warszawska (PL)
Krawczyk R.D.-Politechnika Warszawska (PL)
30p.
21.Demchenko I.N., Melikhov Y., Syryanyy Y., Zaytseva I., Konstantynov P., Chernyshov M., Effect of argon sputtering on XPS depth-profiling results of Si/Nb/Si, JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, ISSN: 0368-2048, DOI: 10.1016/j.elspec.2017.09.009, Vol.224, pp.17-22, 2018

Streszczenie:

Ultrathin Si/Nb/Si trilayer is an excellent example of a system for which dimensionality effects, together with other factors like type of a substrate material and growth method, influence strongly its superconducting properties. This study offers some important insights into experimental investigation of density of states of such a system with the aim to identify an electronic structure of the interface as a function of niobium layer thickness. For that, two Si/Nb/Si trilayers with 9.5 and 1.3 nm thick niobium layer buried in amorphous silicon were studied using high-resolution (HR) XPS depth-profile techniques. Strong influence of sputtering was observed, which resulted in severe intermixture of Si and Nb atoms. Nevertheless, a sharp top interface and metallic phase of niobium were detected for the thicker layer sample. On the contrary, a Nb-rich mixed alloy at top interface was observed for the thinner layer sample.

Słowa kluczowe:

High-resolution X-ray photoelectron spectroscopy, XPS, Si/Nb/Si, NbSi, Depth profiling

Afiliacje autorów:

Demchenko I.N.-Institute of Physics, Polish Academy of Sciences (PL)
Melikhov Y.-IPPT PAN
Syryanyy Y.-Institute of Physics, Polish Academy of Sciences (PL)
Zaytseva I.-Institute of Physics, Polish Academy of Sciences (PL)
Konstantynov P.-Institute of Physics, Polish Academy of Sciences (PL)
Chernyshov M.-Institute of Plasma Physics and Laser Microfusion (PL)
25p.

Prace konferencyjne
1.Demchenko I.N., Melikhov Y., Konstantynov P., Ratajczak R., Barcz A., Guziewicz E., Resonant Photoemission Spectroscopy Study on the Contribution of the Yb 4f States to the Electronic Structure of ZnO, ACTA PHYSICA POLONICA A, ISSN: 0587-4246, DOI: 10.12693/APHYSPolA.133.907, Vol.133, No.4, pp.907-909, 2018

Streszczenie:

The electronic structure of Yb implanted ZnO has been studied by the resonant photoemission spectroscopy. The contribution of the Yb 4f partial density of states is predominant at binding energy about 7.5 and approximate to 11.7 eV below the VB maximum. At photon energy about 182 eV the multiplet structure around 11.7 eV shows the strongest resonance that corresponds to the I-1 multiplet which is almost exclusively responsible for this resonance, while H-3 and F-3 states are responsible for the resonance around 7.5 eV. It was also found that the Yb 4f partial density of states distribution shows some similarity to Yb2O3.

Afiliacje autorów:

Demchenko I.N.-Institute of Physics, Polish Academy of Sciences (PL)
Melikhov Y.-IPPT PAN
Konstantynov P.-Institute of Physics, Polish Academy of Sciences (PL)
Ratajczak R.-National Centre for Nuclear Research (PL)
Barcz A.-Institute of Physics, Polish Academy of Sciences (PL)
Guziewicz E.-Institute of Physics, Polish Academy of Sciences (PL)
20p.

Abstrakty konferencyjne
1.Melikhov Y., Ekiel-Jeżewska M.L., Attracting modes of sedimentation for highly elastic fibers settling under gravity in a viscous fluid, Bulletin of the American Physical Society, ISSN: 0003-0503, Vol.68, pp.ZC34.00006, 2023
2.Honnenahalli S.J., Melikhov Y., Ekiel-Jeżewska M.L., Attraction and repulsion of a pair of sedimenting ball-chains at low reynolds number, Bulletin of the American Physical Society, ISSN: 0003-0503, Vol.66, pp.P15.3, 2021
3.Melikhov Y., Gruziel-Słomka M., Ekiel-Jeżewska M.L., Flexible loops settling under gravity in a viscous fluid, Bulletin of the American Physical Society, ISSN: 0003-0503, Vol.66, pp.A23.9, 2021
4.Melikhov Y., Ekiel-Jeżewska M.L., Jas G.S., Kuczera K., Hydrodynamic approach to compute reorientation times of NATA protein in different solutions: comparison with Molecular Dynamics and experiment, APS/DFD 2019, 72nd Annual Meeting of the APS Division of Fluid Dynamics, 2019-11-23/11-26, Seattle (US), pp.1, 2019