1.Guo T., Ma Y-J., High R.A., Tang Q., Wong J.H., Byra M., Searleman A.C., To S.C., Wan L., Le N., Du J., Chang E., Assessment of an in vitro model of rotator cuff degeneration using quantitative magnetic resonance and ultrasound imaging with biochemical and histological correlation, European Journal of Radiology, ISSN: 0720-048X, DOI: 10.1016/j.ejrad.2019.108706, Vol.121, pp.108706-1-10, 2019

Streszczenie:

Purpose: Quantitative imaging methods could improve diagnosis of rotator cuff degeneration, but the capability of quantitative MR and US imaging parameters to detect alterations in collagen is unknown. The goal of this study was to assess quantitative MR and US imaging measures for detecting abnormalities in collagen using an in vitro model of tendinosis with biochemical and histological correlation. Method: 36 pieces of supraspinatus tendons from 6 cadaveric donors were equally distributed into 3 groups (2 subjected to different concentrations of collagenase and a control group). Ultrashort echo time MR and US imaging measures were performed to assess changes at baseline and after 24 h of enzymatic digestion. Biochemical and histological measures, including brightfield, fluorescence, and polarized microscopy, were used to verify the validity of the model and were compared with quantitative imaging parameters. Correlations between the imaging parameters and biochemically measured digestion were analyzed. Results: Among the imaging parameters, macromolecular fraction (MMF), adiabatic T1p, T2*, and backscatter coefficient (BSC) were useful in differentiating between the extent of degeneration among the 3 groups. MMF strongly correlated with collagen loss (r=-0.81; 95% confidence interval [CI]: -0.90,-0.66), while the adiabatic T1p (r = 0.66; CI: 0.42,0.81), T2* (r = 0.58; CI: 0.31,0.76), and BSC (r = 0.51; CI: 0.22,0.72) moderately correlated with collagen loss. Conclusions: MMF, adiabatic T1p, and T2* measured and US BSC can detect alterations in collagen. Of the quantitative MR and US imaging measures evaluated, MMF showed the highest correlation with collagen loss and can be used to assess rotator cuff degeneration.

Słowa kluczowe:

rotator cuff tendon, tendinopathy, quantitative MRI, UTE, quantitative ultrasound

Afiliacje autorów:

Guo T.-University of California (US)
Ma Y-J.-University of California (US)
High R.A.-University of California (US)
Tang Q.-University of California (US)
Wong J.H.-University of California (US)
Byra M.-IPPT PAN
Searleman A.C.-University of California (US)
To S.C.-University of California (US)
Wan L.-University of California (US)
Le N.-University of California (US)
Du J.-University of California (US)
Chang E.-University of California (US)
100p.
2.Byra M., Wan L., Wong J.H., Du J., Shah SB., Andre M.P., Chang E.Y., Quantitative ultrasound and b-mode image texture featurescorrelate with collagen and myelin content in human ulnarnerve fascicles, ULTRASOUND IN MEDICINE AND BIOLOGY, ISSN: 0301-5629, DOI: 10.1016/j.ultrasmedbio.2019.02.019, Vol.45, No.7, pp.1830-1840, 2019

Streszczenie:

We investigate the usefulness of quantitative ultrasound and B-mode texture features for characterization of ulnar nerve fascicles. Ultrasound data were acquired from cadaveric specimens using a nominal 30-MHz probe. Next, the nerves were extracted to prepare histology sections. Eighty-five fascicles were matched between the B-mode images and the histology sections. For each fascicle image, we selected an intra-fascicular region of interest. We used histology sections to determine features related to the concentration of collagen and myelin and ultrasound data to calculate the backscatter coefficient (–24.89 ± 8.31 dB), attenuation coefficient (0.92 ± 0.04 db/cm-MHz), Nakagami parameter (1.01 ± 0.18) and entropy (6.92 ± 0.83), as well as B-mode texture features obtained via the gray-level co-occurrence matrix algorithm. Significant Spearman rank correlations between the combined collagen and myelin concentrations were obtained for the backscatter coefficient (R = –0.68), entropy (R = –0.51) and several texture features. Our study indicates that quantitative ultrasound may potentially provide information on structural components of nerve fascicles.

Słowa kluczowe:

nerve, quantitative ultrasound, high frequency, histology, pattern recognition, texture analysis

Afiliacje autorów:

Byra M.-IPPT PAN
Wan L.-University of California (US)
Wong J.H.-University of California (US)
Du J.-University of California (US)
Shah SB.-University of California (US)
Andre M.P.-University of California (US)
Chang E.Y.-University of California (US)
70p.

Abstrakty konferencyjne
1.Byra M., Wong J., Shah S., Han A., O Brien W., Du J., Chang E., Andre M., High-frequency quantitative ultrasound and B-mode analysis for characterization of peripheral nerves including carpal tunnel syndrome, ASA, 178th Meeting of the Acoustical Society of America, 2019-12-02/12-06, San Diego (US), DOI: 10.1121/1.5136729, Vol.146, No.4, pp.2809-2809, 2019

Streszczenie:

We investigated the use of high-frequency quantitative ultrasound (QUS) and B-mode texture features to characterize ulnar and median nerve fascicles using a clinical scanner (Vevo MD) and a 30-MHz center-frequency probe. US correlation with histology was first investigated in the ulnar nerve in situ in cadaveric specimens. 85 fascicles were matched in B-mode images and the histology sections. Collagen and myelin concentrations were quantified from trichrome labeling, and backscatter coefficient (-24.89 ± 8.31 dB), attenuation coefficient (0.92 ± 0.04 dB/cm MHz), Nakagami parameter (1.01 ± 0.18) and entropy (6.92 ± 0.83) were calculated from ultrasound data. B-mode texture features were obtained via the gray-level co-occurrence matrix algorithm. Combined collagen and myelin concentration were significantly correlated with the backscatter coefficient (R = -0.68), entropy (R = -0.51), and several texture features. For the median nerve, we measured backscatter and morphology in 10 patients with carpal tunnel syndrome and 21 healthy volunteers. Significant differences (<0.01) between patients and controls and AUC 0.89–0.94 for QUS biomarkers were observed. Our study indicates that QUS may potentially provide useful information on structural components of even very small nerves (2 × 4 mm) and fascicles for diagnosing and monitoring injury, and surgical planning.

Afiliacje autorów:

Byra M.-IPPT PAN
Wong J.-University of California (US)
Shah S.-University of California (US)
Han A.-University of Illinois at Urbana-Champaign (US)
O Brien W.-University of Illinois at Urbana-Champaign (US)
Du J.-University of California (US)
Chang E.-University of California (US)
Andre M.-University of California (US)